Chiller and Rooftop Package Maintenance: A Yearly Checklist for Building Owners
Published on November 27, 2026 · NAD Toseeh Paydar Team

Chiller and Rooftop Package Maintenance: A Yearly Checklist for Building Owners

Chillers and rooftop package units run for thousands of hours a year, often in dust, heat and rain. Most breakdowns in the first years do not come from a design fault. They come from missed routine care. This checklist covers the main points. Always follow the maintenance manual of your specific equipment, because intervals and procedures differ between manufacturers and operating conditions.

Airside: filters and coils

  • Check and clean or replace air filters on the schedule in the manual. Blocked filters reduce airflow and raise energy use.
  • Inspect the condenser and evaporator coils. Dirt on a coil acts as insulation and the unit works harder for the same cooling.
  • Check fins for damage and straighten bent fins carefully.

Fans and drives

  • Listen for unusual noise or vibration, and check fan blades and mountings.
  • On belt-driven units, check belt wear and tension; on direct-drive units, check bearings and motor current.

Refrigerant circuit

  • Have a qualified technician check pressures and look for signs of leaks such as oil traces at joints.
  • Low cooling with normal airflow can point to a refrigerant problem; do not just add refrigerant without finding the cause.

Water side (for chillers)

  • Check pump operation, flow and strainers, and look for leaks at valves and joints.
  • Keep the water treatment and glycol concentration (where used) at the level the designer specified.
  • Check the expansion tank and system pressure.

Electrical and controls

  • Check terminals for tightness and signs of heat, and check contactors and the starter or drive.
  • Test safety devices and alarms, and confirm that the controller settings and schedules are still correct. The condition of the supply panel matters too; see our notes on electrical panels.

Condensate and the rooftop itself

  • Clear condensate drains so water does not back up into the unit or onto the roof.
  • Check panels, seals, weatherproofing and the curb or frame for corrosion and loose fixings.

Warning signs to act on early

Rising electricity use with no change in load, longer run times, icing on the coil, tripping safety devices, new noises and uneven cooling are all signs that something needs attention. Early action is usually cheaper than waiting for a failure in the hottest week of the year.

What to ask a service contractor

Ask for a written scope that lists each item above, how often it is done, what spare parts are included and what the response time is for a breakdown. Keep a log of readings so changes over time are visible. If you are planning a new installation, our rooftop chiller installation checklist and chiller quote checklist help you get the design right from the start.

NAD supplies and installs HVAC equipment for commercial and industrial projects. See our HVAC page or send a request for supply, installation or a maintenance discussion.